Job Locations
for palm coast, fl

Dave P.

Dave P. Job Checkin

Air Conditioning Service: UPSTAIRS SYSTEM


Dave P.

Dave P. Job Checkin

Air Conditioning Service: UPSTAIRS SYSTEM


Dave P.

Dave P. Job Checkin

Air Conditioning Service: MAIN SYSTEM DOWNSTAIRS


Dave P.

Dave P. Job Checkin

Air Conditioning Service: MASTER BEDROOM SYSTEM


Randy H.

Randy H. Job Checkin

Air Conditioning Service: STARTED UP NEW SYSTEM


Jeff N.

Jeff N. Job Checkin

Air Conditioning Service: HOOKED UP RANGE HOOD


David F.

David F. Job Checkin

Air Conditioning Service: KOONTZ A/C WAS HERE SATURDAY, FOUND OUTDOOR FAN MOTOR SEIZED, REPLACED OUTDOOR FAN MOTOR 5464 & 7.5 UF CAP, STARTED AND CHECKED OPERATION AND UNIT IS NOW OPERATING


David F.

David F. Job Checkin

Air Conditioning Service: FOUND BLOWER MOTOR AND MODULE ARE BOTH OPEN ,WILL NEED TO REPLACE MOTOR AND MODULE TO GET SYSTEM BACK ONLINE


David F.

David F. Job Checkin

Air Conditioning Service: LAST VISIT 4/28/17 ,FOUND FAN SIDE OF DUAL CAP OPEN, ATTEMPTED NEW CAP AND FOUND THAT MOTOR IS OPEN, WILL NEED NEW MOTOR 5464 & CAP


David F.

David F. Job Checkin

Air Conditioning Service: FOUND CONDENSATE DRAIN PARTIALLY PLUGGED, TRIPPING THE FLOAT SWITCH, CYCLING SYSTEM ON AND OFF ,CLEANED AND FLUSHED DRAIN, TESTED DRAIN AND NOW FLOWS PROPERLY AT THIS


John C.

John C. Job Checkin

Air Conditioning Service: SEALED WHERE LINES WENT INTO WALL. SEALED WHERE THERMOSTAT WIRES WENT INTO WALL. 3 SYSTEMS.


Mark M.

Mark M. Job Checkin

Air Conditioning Service: TD20


John P.

John P. Job Checkin

Air Conditioning Service: UNIT ICING UP DUE TO FAILED BLOWER MOTOR THAT WILL NOT RUN WITH HIGH AND LOW VOLTAGES PRESENT. QUOTED PART OVER PHONE AND WILL ORDER.


John P.

John P. Job Checkin

Air Conditioning Service: UNIT HAS MULTIPLE COMM FAULTS INCLUDING NO SYSTEM CLK FROM LOSS OF BIT MASTER. SERVICE FACTS STATES TO REPLACE AFC BOARD. ORDERING NEW AFC BOARD UNDER PARTS ONLY WARRANTY.


John P.

John P. Job Checkin

Air Conditioning Service: UNIT NOISE IS NORMAL COMPRESSOR NOISE. CUSTOMER HAS NEWER UNIT WITH LOWER DECIBEL RATING NEXT TO IT. CUSTOMER WANTS QUOTE FOR SAME MODEL AS NEWER AS HE LIKES THE QUITE